史賽克Stryker 6206-000-000電鉆骨鉆維修更換
品牌名稱:史塞克Stryker
維修類型:電鉆骨鉆維修
維修型號(hào):6206-000-000
詳細(xì)配置與設(shè)備參數(shù):
Type : Battery Handpiece
Manufacturer : Stryker
Part Number : 6206-000-000
System 6 Family :6203 Stryker System 6 Single Trigger Rotary Drill6205?Stryker System 6 Double Trigger Rotary Drill6206?Stryker System 6 Reciprocating Saw6207?Stryker System 6 Sternum Saw6208 Stryker System 6 Sagittal?Saw6209 Stryker System 6 Precision Saw
Compatible Batteries : 6212-000-000 Stryker System 6 Battery, Small6215-000-000?Stryker System 6 Battery, Large, Blue6215-STR-6000 AA?System 6 Battery, Large
Battery Charger : 6110-120 Stryker System 6 Battery Charger7110-120 Stryker System 7 Battery Charger
Compatible Blades : System 6 Reciprocating Saw Blades

維修項(xiàng)目:
1.維修更換電動(dòng)骨鉆電機(jī);
2.維修更換電動(dòng)骨鉆軸承組件;
3.維修更換骨鉆控制按鈕與按鈕;
4.維修更換電鉆前端夾頭、接頭等;
常見(jiàn)故障:
1.骨鉆不能轉(zhuǎn)動(dòng)或發(fā)熱過(guò)大;
2.電動(dòng)骨鉆轉(zhuǎn)速低;
3.軸承卡死、斷裂、磨損嚴(yán)重;
4.轉(zhuǎn)數(shù)控制失靈;
相關(guān)維修設(shè)備與配件:
史賽克Stryker AO /快速連接小型附件 設(shè)備編號(hào):6203-110-000
史賽克Stryker Hudson鉆頭附件 設(shè)備編號(hào):6203-113-000
斯崔克1/4“雅各布斯卡盤 設(shè)備編號(hào):6203-131-000
史賽克1/4“雅各布斯卡盤 設(shè)備編號(hào):6203-131-000-New
斯崔克1/4“無(wú)鑰雅各布斯卡盤 設(shè)備編號(hào):6203-133-000
FUJINON富士能EG-450CT5胃鏡維修
動(dòng)力系統(tǒng)維修美敦力AF01驅(qū)動(dòng)附件維修項(xiàng)目
動(dòng)力系統(tǒng)維修medtronic18-97200更換電機(jī)找哪里